Typical Technical Specifications:
Introduction
Hingelock deployer Model 625 was developed to
conduct electric field measurements for the Interactive
Measurements Payload for Shuttle (IMPS) program. This
motorized unit is capable of extending and retracting
a 1.12 inch (2.86 cm) diameter by 32.8 foot (10 meter)
long Tubular Extendible Element (TEE). The deployer
features electrical and mechanical stops at
full-extension and -retraction. A potentiometer, driven
by the moving element, provides a continuous
indication of deployed length. To ensure minimal
distortion due to thermal gradients in a space environ-
ment, material perforations and thermal control
coatings are applied on both the inside and outside TEE
surfaces. An optional motor driven TEE cut-off device
may be added to the configuration shown above. This
deployment mechanism is designed to meet the require-
ments of document MIL-A-083577 (USAF) General
Specification for Moving Mechanical Assemblies for
Space and Launch Vehicles. This unit can be deployed
or retracted in orbit.
Antenna Element
Deployed Length: Up to 32.8 ft
(10 meters)
Diameter: 1.12 in (2.86 cm)
Configuration: Hingelock
Material: Beryllium Copper
0.0045 in
(0.1143 mm) thick
Thermal Control Silver &
Coating: Perforations with
Kapton or Teflon
(if required)
Weight 31.43 gr/ft
(with coatings): (103.12 gr/m)
Deployer
Height: 8.23 in (20.9 cm)
Length: 22 in (55.9 cm)
Width: 6.81 in (17.3 cm)
Total Unit Weight:* 15 lbs (6.7 kg)
Drive Motor: Brushless D.C.
Power: 14 Watts maximum
Voltage: 24-32 Vdc
Deployment Rate: Approximately
1.2 in/sec
(3 cm/sec)
Operating
Temperature Range: -20°C to +70°C
*w/o TEE Cut-Off Device